2018 Generac 40kW Diesel Generator SD040

Call for Price


Availability
Brochure
Year
2018
Manufacturer
Generac
Model
40kW Diesel Generator SD040

Overview

Description

The safety of your staff and customers is a must. Power for lighting and electrically-controlled entrances/exits during a power outage will help keep everyone safe. Plus, maintaining power to your security systems will keep your inventory protected.

Features
  • Generator Enclosure: Generac manufactures its own enclosures, ensuring each unit combines the highest level of durability, noise reduction, weather resistance, and streamlined design.
  • Industrial Alternator: Generac industrial alternators are machine wound, machine inserted, and machine varnished for the ultimate in consistency.
  • PowerManager® Controller: Generac engineers its generator controls with safety and convenience as top priorities.
Engine Specifications
  • Make: Generac
  • EPA Emissions Compliance: Stationary Emergency
  • EPA Emissions Reference: See Emission Data Sheet
  • Cylinder #: 4
  • Type: In-Line
  • Displacement - in3 (L): 207.48 (3.4)
  • Bore - in (mm): 3.86 (98)
  • Stroke - in (mm): 4.45 (113)
  • Compression Ratio: 18.5:1
  • Intake Air Method: Turbocharged/Aftercooled
  • Cylinder Head: Cast Iron OHV
  • Piston Type: Aluminum
  • Crankshaft Type: Forged Steel
Engine Governing
  • Governor: Electronic Isochronous
  • Frequency Regulation (Steady State): ±0.25%
Lubrication System
  • Oil Pump Type: Gear
  • Oil Filter Type: Full Flow Cartridge
  • Crankcase Capacity - L (qts): 7.4 (7)
Cooling System
  • Cooling System Type: Closed Recovery
  • Water Pump Type: Pre-Lubed, Self Sealing
  • Fan Type: Pusher
  • Fan Speed - rpm: 2,250
  • Fan Diameter - in (mm): 560 (22)
Fuel System
  • Fuel Type: Ultra Low Sulfur Diesel Fuel #2
  • Fuel Specifications: ASTM
  • Fuel Filtering (microns): 10
  • Fuel Injection: Bosch (VE)
  • Fuel Pump Type: Engine Driven Gear
  • Injector Type: Pintel - 2,100 psi (14,479 kPa)
  • Fuel Supply Line mm (in): 0.312 (7.92) NPT
  • Fuel Return Line mm (in): 0.312 (7.92) NPT
Engine Electrical System
  • System Voltage: 12 VDC
  • Battery Charger Alternator: Standard
  • Battery Size: See Battery Index 0161970SBY
  • Battery Voltage: 12 VDC
  • Ground Polarity: Negative
Alternator Specifications
  • Standard Model: Generac 390 mm
  • Poles: 4
  • Field Type: Revolving
  • Insulation Class - Rotor: H
  • Insulation Class - Stator: H
  • Total Harmonic Distortion: <5% (3-Phase)
  • Telephone Interference Factor (TIF): < 50
  • Standard Excitation: Synchronous Brushless
  • Bearings: Single Sealed Cartridge
  • Coupling: Direct via Flexible Disc
  • Load Capacity - Standby: 100%
  • Prototype Short Circuit Test: Yes
  • Voltage Regulator Type: Digital
  • Number of Sensed Phases: All
  • Regulation Accuracy (Steady State): ±0.25%

Specs

Engine

Engine Type
Generac In-Line 4
Horsepower
65 hp
Displacement
3.4 L (207.48 cu.in.)

Dimensions

Length
76 in. (1930.4 mm)
Width
38 in. (914.4 mm)
Height
45 in. (1143 mm)
Weight
1756 lb. (796 kg)

Other

AC Output
40 kW

Related Products